VIS Bandpass filter
VIS Bandpass filter

678/18nm Bandpass Optics Filter

678/18nm Bandpass Optics Filter is designed to transmit light centered 678nm and FWHM 18nm. Coligh manufactures EUV to IR optical bandpass filter.

It has features below:

  • Center wavelength 678nm
  • FWHM 18nm
  • Transmission above 90%
  • Blocking depth OD>=6
  • ION Assisted Hard Coating
Products Categories
Get A Free Quote
Contact Form Demo (#3)

Hard-Coated 678/18nm Narrowband Interference Filter Description

678/18nm Bandpass Optics Filter Coligh manufactures A high-performance optical component based on multilayer dielectric film interference technology, designed for spectrally selective transmission in the 678 nm near-infrared band. This product is a hard-coated interference bandpass filter. We achieve narrow-band high transmission and deep blocking OD>=6 through the precise stacking of 60–150 layers of high/low refractive index oxide films

  • Central wavelength 678+/-1nm, covering the transition zone from red light to near-infrared, including some fluorescent probe emissions and characteristic spectra of semiconductor materials
  • Half bandwidth 18+/-1nm, passband range 669–687 nm, 18 nm ultra-narrow bandwidth accurately isolates target signals and suppresses interference from adjacent bands.
  • The transmittance in the passband is greater than or equal to 90%, and the blocking rate outside the passband is greater than or equal to OD6 at 350-1000nm, achieving wide-spectrum deep blocking
  • We use fused quartz JGS1 as the substrate. In addition to the low thermal properties of autofluorescence, the film adhesion and density are also high.
  • We support customization of any wavelength, bandwidth, material, size, and shape, and provide 10–15 days rapid prototype delivery to reduce customer R&D cycle and comprehensive cost.

678/18nm Bandpass Optics Filter Technical Datasheet

Parameter Specification
Center Wavelength (CWL) 678± 1 nm
Full Width at Half Maximum (FWHM) 18nm± 1 nm
Peak Transmission 90%
Blocking Range 350-1000nm
Optical Density (OD) OD ≥ 6 outside passband
Angle of Incidence (AOI) 0° +/-5°
Surface Quality 60/40 scratch-dig (per MIL-PRF-13830B)
Material Substrate Fused Silica JGS1
Coating Type Hard-Coated Interference Filter/ IAD Assisted Coating
Thickness 1mm  (typical)
Filter Dimensions Custom sizes available (e.g., Ø12.5 mm, 60×60 mm)
Clear Aperture >90% of physical size
Operating Temperature -40°C to +85°C

678/18nm Bandpass Optics Filter Applications

  1. Biomedicine
    In vivo imaging requires the detection of near-infrared fluorescent probes, Cy5.5’s 678 nm emission light, but the autofluorescence of biological tissues <650 nm and the residual 640 nm excitation light will interfere with weak signals. The 678/18nm filter can only allow 669-687 nm fluorescence signals to pass through, shielding stray light of other wavelengths. The 18 nm narrow-band pass window matches the probe emission peak, suppressing autofluorescence below 650 nm and ambient light above 690 nm. In addition, the 678 nm near-infrared band has a penetration depth of 8-10 mm, which is suitable for tumor microenvironment monitoring.
  2. Industrial detection
    The nano-scale metal residues of copper and aluminum on semiconductor wafers have significant differences in reflectivity at 678 nm, requiring high-contrast imaging to locate defects, but workshop lighting interference will reduce the signal-to-noise ratio. This filter can be used with a 678 nm LED light source to receive only 669-687 nm reflection signals. Blocking visible light and far-infrared light), highlighting the reflection characteristics of defects. And the 18 nm narrowband reduces optical chromatic aberration and supports submicron defect recognition.
  3. LiDAR
    The autonomous driving LiDAR system uses 678 nm laser to detect obstacles, but the interference of sunlight 650-700nm will cause point cloud noise. The 678/18nm narrowband filter covers the LiDAR receiving sensor and only allows 678±9 nm laser echo signals to pass. Blocking the bands other than 669–687 nm in sunlight, the high transmittance maximizes the echo signal strength and improves the accuracy of obstacles
  4. Medical equipment
    Non-invasive blood oxygen monitoring is based on the difference in hemoglobin absorption of 678 nm and 940 nm, but skin melanin and tissue scattering will reduce signal accuracy. The 678/18nm optical filter can be paired with a 940 nm filter to transmit only the 678±9 nm absorption signal.

Get Free Quote Of 78nm Bandpass Filter for Fluorescence Microscopy Systems

Related News

Scroll to Top

Get A Free Quote Now !

Contact Form Demo (#3)
If you have any questions, please do not hesitate to contact us.
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.